Table 2 Model parameters for the rate of risks and adverse events attributed to strategies

From: Transcatheter aortic valve implantation against conventional aortic valve replacement surgery in high-risk patients with aortic stenosis; a cost-effectiveness analysis

Rate of adverse events and Probability of transition

Base Case

Source

Transient ischemic attack (TIA) TAVI

0.053

[20]

Transient ischemic attack (TIA) SAVR

0.043

[20]

Stroke (TAVI)

0.153

[20]

Stroke (SAVR)

0.125

[20]

Rehospitalization (TAVI)

0.333

[20]

Rehospitalization (SAVR)

0.252

[20]

Myocardial infarction (TAVI)

0.111

[20]

Myocardial infarction (SAVR)

0.082

[20]

New atrial fibrillation (TAVI)

0.158

[20]

New atrial fibrillation (SAVR)

0.304

[20]

New permanent pacemaker implantation (TAVI)

0.155

[20]

New permanent pacemaker implantation (SAVR)

0.13

[20]

Aortic-valve reintervention (TAVI)

0.032

[20]

Aortic-valve reintervention (SAVR)

0.008

[20]

Transient ischemic attack (TIA) TAVI

0.053

[20]

Transient ischemic attack (TIA) SAVR

0.043

[20]

Probability of being at NYHA I) TAVI (0–12 months)

0.36

[14]

Probability of being at NYHA II) TAVI (0–12 months)

0.28

[14]

Probability of being at NYHA III) TAVI (0–12 months)

0.10

[14]

Probability of being at NYHA IV) TAVI (0–12 months)

0.01

[14]

Probability of death for any causes TAVI (0–12 months)

0.25

[14]

Probability of being at NYHA I) SAVR (0–12 months)

0.34

[14]

Probability of being at NYHA II) SAVR (0–12 months)

0.30

[14]

Probability of being at NYHA III) SAVR (0–12 months)

0.07

[14]

Probability of being at NYHA IV) SAVR (0–12 months)

0.02

[14]

Probability of death for any causes SAVR (0–12 months)

0.27

[14]